mri
mri
mri
mri +91-995-362-5888
mri info@bionationimaging.com
MRI
mri
    Refurbished Siemens MAGNETOM C 0.35T Features
  1. 270° accessibility & patient-friendly sideloading
  2. Largest anatomical coverage in mid-field MRI
  3. Parallel Imaging in all directions & head to toe
  4. 3D exams with double oblique slice orientation
  5. 32-channel 3T system for accelerations up to PAT 16
  6. Whole body RF scanning
  7. Full-body sized bore for whole body imaging in one scan
  8. AudioComfort to reduce acoustic noise by up to 90%
mri
    Refurbished Siemens MAGNETOM Symphony 1.5T Features
  1. Integrated Panoramic Array™ (IPA) coil technology
  2. Scan an L-spine in less than one minute
  3. High-resolution 3D breast exams with parallel imaging standard with syngo VIEWS
  4. Upgradable to TIM® (Total imaging matrix) technology
  5. Applications

    Angiography, Breast, Cardiac, Neurology, Vascular Imaging, Whole Body Imaging

mri
    Hitachi AIRIS II Open MRI

    Gantry

  1. Award winning asymmetrical, panoramic design
  2. Gap: 43cm (17in)
  3. Table

  4. Width: 80cm (31.5in)
  5. Drop: 45cm (17.7in)
  6. Weight Limit: 500lbs
  7. 2-speed power-driven longitudinal movement

Computer

  1. 64 Bit RISC-based architecture
  2. DICOM 3.0 compatible
  3. 1GB Memory
  4. LCS Color Display

Hitachi AIRIS II Magnet

  1. Permanent 0.3 Tesla
  2. Vertical Orientation
  3. Self-shielded
  4. 6.6'(h) x 8.2'(v) 5 Gauss fringe field
  5. 3-axis per patient shim
  6. Post-to-post: 110cm (43.3in)

Hitachi AIRIS II Technical Specifications (Tech Specs)

  1. Magent: Self-shielded, Permanent
  2. Bore: 110 x 43cm (w x h)
  3. Magnet Weight: 15,700kg (34,540 lbs.)
  4. Magnet Dimensions: 79 x 111 x 73cm
  5. Power Requirements: 208/220/240 VAC, single-phase
  6. Cooling System: Air-cooled
  7. 5-GAUSS Fringe Field: 2.0 m lateral, 2.5 m vert./long
  8. Shimming: Auto shimming, 3-axis/patient, and volume shim
  9. Clinical Application: Whole Body
  10. Configuration: Open MRI, Vertical Field
  11. Spectroscopy: No
  12. Synchronization: Cardiac gating, ECG/peripheral, respiratory gating (2 modes)
  13. Pulse Sequences (Standard): SE, GE, GR, IR, FIR, STIR, FSE, ss-FSE, FLAIR, EPI -DWI, SE-EPI, ms - EPI, SSP, MTC, SARGE, RSSG, TRSG, MRCP, Angiography: CE, 2D/3D TOF
  14. Imaging Modes: Single, multislice, volume study
  15. TR: SE: 30 - 10,000msec GE: 20 - 10,000msec IR: 50 - 16,700msec FSE: 200 - 16,7000msec
  16. TE: SE : 10 - 250msec IR: 10 -250msec GE: 5 - 50 msec FSE: 15 - 2,000
  17. Single/ Multi Slice: 0.05 sec/image (256 x 256)
  18. FOV: 5cm to 42 cm continuous
  19. Slice Thickness: 2D: 2 - 10 mm; 3D: 0.5 - 5mm
  20. Display Matrix: 1280 x 1024
  21. Measuring Matrix: 512 x 512?
  22. Pixel Intensity: Level Range: -2,000 to +4,000
  23. Spatial Resolution: Sub millimeter

mri
    Hitachi AIRIS I Open MRI

    Gantry

  1. Award winning asymmetrical, panoramic design
  2. Gap: 43cm (17in)
  3. Table

  4. Width: 80cm (31.5in)
  5. Drop: 45cm (17.7in)
  6. Weight Limit: 500lbs
  7. Two speed, power-driven longitudinal movement

Computer

  1. DICOM 3.0 compatible
  2. 16MB Memory
  3. High Resolution Display (512 x 512)

Magnet

  1. Permanent 0.3 Tesla
  2. Vertical Orientation
  3. Self-shielded
  4. 6.6'(h) x 8.2'(v) 5 Gauss fringe field
  5. 3-axis per patient shim
  6. Post-to-post: 110cm (43.3in)